Lamp options and paint

Colour requirements for manufacture and retail are complex and diverse. To ensure product colour is consistent several types of light source are used within a Colour Assessment Cabinet e.g. Artificial Daylight (D65 or D50), UV, 840, Cool White, Filament and many more. VeriVide recommend that lamps are replaced every 2000 hours or annually to ensure that their colour matching properties are maintained as these properties reduce with time and use even though the lamps continue to illuminate. Cabinets should also be cleaned and repainted annually to ensure that the reflected light and spectral output is not distorted. Replacement lamps and paint may be purchased from VeriVide or one of our global agents or UK customers can book a service of their equipment directly through VeriVide.
Category:

Description

Lamp options and paint

Brand: Verivide, UK.

Often, colours need to be assessed using more than one light source in order to replicate different viewing environments. The need for different light sources becomes apparent when, for example, consumers complain that a product ‘looked different when we got it home’.

When two or more materials match visually under one illuminant but mismatch under another, the inconsistency is termed metamerism. It is most usually caused by differences in the colouring matter used for each material. If only one light source is used for colour assessment, metamerism can easily slip through the net with the potential to cause problems at the consumer interface.

The following table of VeriVide lamps for viewing cabinets covers all supply chain viewing conditions, including the specific requirements of individual major retailers.

Retailers have differing specifications for the lamps and grey used in the Colour Assessment Cabinets. VeriVide equipment provides these conditions for all applications. For consistency, the source of light must be controllable and constant. To understand light sources, two factors need to be considered:

1. COLOUR TEMPERATURE – expressed in Kelvin. (K)
Colour temperature describes the colour appearance of the lamp itself and the light it emits and can vary along with its spectral power distribution. “Correlated” colour temperature applies to fluorescent lamps and approximates the true colour temperature.

  • Lamps with lower colour temperatures appear warmer i.e. red/orange and typical examples would be illuminant A and 830.
  • Lamps with a higher colour temperature look bluer, and examples would include the VeriVide D65 and D75.

2. COLOUR RENDERING INDEX (CRI)
​A numerical system that measures how well colours are rendered by a lamp in comparison to a reference light source. The CRI is measured on an index from 0-100, with 100 representing an exact match, whilst low values indicate poor colour rendering.

  • Therefore a lamp rated with a CRI of 98 such as the VeriVide D65 will show colours more accurately than a lamp with a CRI rating of 62 such as the CWF.

This rating method is recognised by the Illuminating Engineering Society (IES) and the Commission International de L’Eclairage (CIE).

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Lamp options and paint”

Your email address will not be published. Required fields are marked *

What types of textile testing equipment does Visiontex Co. offer?

Visiontex Co. provides a wide range of textile testing equipment, including instruments for testing fabric strength, colorfastness, pilling, abrasion resistance, and more. We aim to support laboratories with accurate and reliable tools for all aspects of textile quality assessment.

Yes, we offer professional calibration services to ensure that your laboratory equipment performs accurately and complies with industry standards. Our team provides certified calibrations and maintains traceability to recognized standards.

Yes, our calibration services are conducted by authorized and certified professionals. We follow rigorous standards and issue calibration certificates that meet industry requirements.

Absolutely! Our team provides end-to-end support, from helping you select the right equipment to guiding you through the installation and calibration processes. We offer comprehensive consultancy for both new and existing textile laboratories.

Yes, we prioritize customer satisfaction by offering ongoing support and training for the equipment we supply. Our experts can guide your team on optimal equipment use and maintenance practices to ensure long-term reliability.

Lead times vary based on equipment availability and your specific requirements. Once we know the products you need, our team will provide an estimated delivery time and keep you updated throughout the process.

You can request a quote by visiting our website and using the contact form, or by reaching out directly via email or phone. Please provide details of your requirements, and our team will respond promptly with a detailed quote.

Yes, we offer maintenance services to keep your equipment in optimal condition. Regular maintenance helps prevent downtime and extends the lifespan of your testing tools.

We partner with reputable manufacturers and conduct rigorous quality checks to ensure that all products meet industry standards for accuracy, durability, and reliability.

We offer flexible payment options to accommodate various customer needs. Please contact our team for details on the available payment methods and terms.

Lamp specifications:

CIE Daylight Illuminants
Light SourceNameLamp DescriptionC.R.I.LengthWattsDiamProduct Code
D75VeriVide D75 "Artificial Daylight"Correlated colour temperature 7500K. Conforming to the USA ASTM (American Society for Testing and Materials) D1729-82 standard for D75 Illuminant. With high CIE specifications, for accurate colour matching.96600mm20wT12600D75
D65VeriVide D65 "Artificial Daylight"VeriVide D65  “Artificial Daylight”.   Correlated colour temperature 6500K. Within the tolerances prescribed in BS 950: Part 1; and all international specifications for D65 illluminant. Specified for most applications where there is a need to maintain colour consistency and quality. Conforming highly to the CIE specifications, for accurate colour matching.98600mm
1200mm
1500mm
18w
36w
58w
T8
T8
T8
600D65
1200D65
1500D65
D50D50 "Artificial Daylight"Correlated colour temperature of 5000K. For the Graphic Technology and Photography industries. D50 lamps conform to BS 950: Part 2 and ISO 3664. Recommended for transmitted light source to view transparencies and for the reflected light source to view reproductions.98600mm
1200mm
1500mm
18w
36w
58w
T8
T8
T8
60095
120095
150095

 

CIE Illuminant 'A'
Light SourceNameLamp DescriptionC.R.I.LengthWattsDiamProduct Code
'F'Tungsten FilamentTungsten Filament Lighting. Approximate colour temperature of 2800K. Required by BS 950: Part 1 as a test for metamerism (approxiamating CIE Illuminant ‘A’). Typical light source used within domestic environments.100Globe
Globe
Round
Clear-284mm
Opal-284mm
40w
60w
150w
60w
60w
45mm
45mm
-
-
-
40G450
60G450
150FILO
28460CL
28460OP
'A'Tungsten HalogenTungsten Halogen Lighting (CIE Illuminant ‘A’). This represents incandescent A (inc-A) with a colour temperature of 2856K. Typical light source used within domestic environments. Used to check for metamerism.100-35w-HALO/12V
/35WLP

 

Alternative (fluorescent) lighting / Point of Sale
Light SourceNameLamp DescriptionC.R.I.LengthWattsDiamProduct Code
840 P15VeriVide 840P15Narrow Band Triphosphor Fluorescent Lamps.   Correlated colour temperature of 4000K.  CIE Illuminant F11. Often chosen as a European “Point of Sale” light source, with good colour rendering and manufactured to a tighter tolerance specification as prescribed by Marks & Spencer. (Formerly TL84P15)85600mm
1200mm
1500mm
18w
36w
58w
T8
T8
T8
60084P15
120084P15
150084P15
CWFCool WhiteCool White Broad Band Fluorescent Lamps. Correlated colour temperature of 4000K. Used as an American “Point of Sale” light source. Moderate colour rendering.62600mm
1200mm
1500mm
20w
40w
65/80w
T12
T12
T12
60033
120033
150033
U35Ultralume 35Ultralume Narrow Band Triphosphor Fluorescent Lamp.Correlated colour temperature 3500K. An American “Point of Sale” light source, with good colour rendering.86600mm
1200mm
17w
32w
T8
T8
T8
600U35
1200U35
830830Narrow Band Triphosphor Fluorescent Lamp.   Correlated colour temperature 3000K. Often chosen as a European “Point of Sale” light source with good colour rendering.(Formerly TL83)85600mm
1200mm
1500mm
18w
36w
58w
T8
T8
T8
60083
120083
150083

 

Horizon
Light SourceNameLamp DescriptionC.R.I.LengthWattsDiamProduct Code
'H'Horizon LightingColour temperature 2300K. Used for Automotive, Apparel and Metamerism Testing. As specified by the ASTM (American Society for testing and Materials) D1729-74, Standard Practise for Visual Evaluation of Colour Differences of Opaque Materials.98-75w-HALO/12V
/75W

 

Ultraviolet
Light SourceNameLamp DescriptionC.R.I.LengthWattsDiamProduct Code
UVUltravioletUltraviolet Blacklight. Used to detect the presence of Optical Brightening Agents and/or Fluorescent dyes. Therefore it is useful when assessing white and Fluorescent shades to check the level present and its evenness.N/AClear-450mm
Blacklight-600mm
15w
18w
T8
T8
450UV15
600UV18

 

Paint specification

PAINT (For Cabinet Interiors)
NameDescriptionQuantityProduct Code
CrownPlain Grey 5574 Matt Emulsion0.5 Litre Tins5574 0.5L
MunsellN50.5 Litre TinsN5 0.5L
MunsellN70.5 Litre TinsN7 0.5L
VERIVIDE MAINTENANCE PACK
The VeriVide Maintenance Pack includes Cleaning Materials, Brush & Roller plus 0.5 litres of Paint. Please specify required paint colour when orderingMAPA

Colour requirements for manufacture and retail are complex and diverse. To ensure product colour is consistent several types of light source are used within a Colour Assessment Cabinet e.g. Artificial Daylight (D65 or D50), UV, 840, Cool White, Filament and many more. VeriVide recommend that lamps are replaced every 2000 hours or annually to ensure that their colour matching properties are maintained as these properties reduce with time and use even though the lamps continue to illuminate. Cabinets should also be cleaned and repainted annually to ensure that the reflected light and spectral output is not distorted. Replacement lamps and paint may be purchased from VeriVide or one of our global agents or UK customers can book a service of their equipment directly through VeriVide.

RELATED PRODUCTS