Autoclaves
Autoclaves(Vertical Type) Microprocessor control with reliable safety functions guarantees optimum sterilization temperature.
Categories: Physical Testing, Shaker,Washer & Dryer
Description
Brand: JEIO TECH
Origin: Korea.Â
Performance
- Microprocessor controller and temperature calibration function allows for high precision temperature control.
– Sterilization temperature at 110 to 123°C
– Melting* temperature at 60 to 100°C
* Liquefaction of coagulated agar media. - Automatic sterilization system for unattended operation.
– Heating > Check safe > Sterilization > Sterilization safe > Exhausting > End - Convenient operation modes for various uses.
– Standard modes and program modes are listed in detail as below tables. - Temperature calibration function.
| Standard modes | Temp. (°C) | Time (min.) |
|---|---|---|
| Decontamination | 121 | 35 |
| Solids sterilization | 121 | 20 |
| Liquids sterilization | 121 | 15 |
| Melting | 100 | 30 |
| Program modes | Temp. (°C) | Time (min.) |
|---|---|---|
| Sterilization 1 | 110 to 123 | 1 to 999 |
| Sterilization 2 | 110 to 123 | 1 to 999 |
| Liquid sterilization | 110 to 123 | 1 to 999 |
| Melting | 60 to 100 | 1 to 999 |
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Only logged in customers who have purchased this product may leave a review.
Convenience
- Conveniently monitored by an independent control display, sterilization process display, and pressure gauge.
- VFD for visualization of temp, pressure (optional), timer, warning alert checks.
- LED lamps for sterilization process check.
- Easy pressure check with the standard gauge attached to the front. - Vertical type autoclaves which allow for top loading are suitable for high volume sterilization.
- Baskets are stackable two high or even more levels, which secure inside the chamber space requirements. - Low-maintenance
- The chamber is constructed of stainless steel which is superiorly resistant to corrosion.
- Easy to replace silicone gasket. - Convenient documentation with the optional data recorder.
- Dot type recorder(6 point)Â allows for precise documentation.
Safety
- Mechanical safety devices
- Over current protection.
- Over temperature protection by automatic power cutoff.
- Over pressure protection by automatic and manual safety valve. - Safety warning systems
- Over temperature warning.
- Low temperature warning.
- Low water level warning.
- Low heat warning if the temperature does not reach the sterilization or melting temperature.
- Sterilization fail warning if the operation is unexpectedly stopped during sterilization process. - Slide opening door with plastic cover of low thermal conductivity prevents burns from the contact.
RELATED PRODUCTS
Brix Refractometer
Sugar is one of the most tested content in food processing. Sugar concentrations are measured in the units of Brix. Various models with different display resolutions or scales are available for selection. Choose one with the range that is nearest to your measured value. A meter with a narrow range will give you higher resolution and accuracy.
Buffer Solution & Calibration Solutions
Calibration Standards are an important part of the measuring system. Without which, the measuring meter is redundant. Trans Instruments makes its best efforts in adhering to strict standards of conformance to the National Institute of Standard Test Methods (NIST). These solutions are tested against instruments calibrated against certified standards. Each standard solution is made in soluble form, sealed and date coded to ensure the highest quality and accuracy when delivered. Never compromise with using power form standards which require mixing and handling.